Radiant heat warms the room from the floor up: no blowing air, no dust stirred up, no cold spot by the window while the thermostat says 70. It's the most comfortable heat there is, and because the heat travels through water in pipes, it's plumbing work. We design and install hot-water (hydronic) radiant floors, and we repair, service and replace the boilers that run them β along with baseboard and radiator systems in older homes.
Call (865) 284-2424 for a boiler repair or a radiant heating estimate anywhere in Knox, Blount, Anderson and Loudon counties.
Where Radiant Floor Heating Makes Sense in East Tennessee
Most Knoxville homes heat with a heat pump or gas furnace, and for many of them that's the right call. Radiant earns its place in specific spaces:
- Basements on a concrete slab. A finished basement on the hillside lots common around West Knoxville and Farragut stays cold underfoot no matter what the vents do. Tubing in or under the slab fixes that.
- New builds and additions. When the floor is open, laying tubing before the pour or the subfloor is the cheapest radiant you'll ever install.
- Tile and stone floors. Kitchens, mudrooms and master baths with tile are where people feel the difference most.
- Garages and workshops. A heated slab keeps a shop usable all winter, and opening the overhead door doesn't dump the heat the way it does with forced air.
We'll also tell you when it doesn't fit. Tearing up finished floors throughout a house to retrofit radiant rarely pays off in a climate this mild β a ductless mini-split is often the better fix for one cold room. And for a single small bathroom, an electric heating mat under the tile can cost less than a hot-water loop; that's electrician work, and we'll say so.
How We Install a Hydronic Radiant Floor
- Heat-loss calculation. We size the system to the room β insulation, windows, slab edge β so the floor holds temperature on a 15Β°F January night without running hot.
- Tubing layout. PEX tubing goes into a new slab, a thin pour over an existing floor, or aluminum heat-transfer plates under the subfloor from below, spaced closer along exterior walls where heat loss is highest.
- Manifold, pump and mixing valve. Each room or zone gets its own loop and thermostat. A mixing valve keeps floor water around 85β120Β°F, well below boiler temperature, so the floor is warm, never hot.
- Pressure test before anything is covered. Every loop is held under pressure before concrete, tile or flooring goes down, so a leak is found while it's still easy to reach.
- Slow startup. New concrete and tile need a gradual warm-up over several days to avoid cracking. We set the schedule and show you the controls.
Boiler Repair: Heat Back On
Call us when you see any of these:
- No heat, or the boiler locks out and won't relight
- One zone or radiator stays cold while the others heat
- Banging, gurgling or a kettle-like rumble from the boiler or pipes
- Water dripping from the pressure relief valve, or the pressure gauge reading well above or below its usual 12β25 PSI
- Water on the floor under the boiler, manifold or a baseboard
Most no-heat calls come down to a failed circulator pump, an expansion tank that has lost its air charge, air trapped in the loops, or an ignition or sensor fault. We carry common parts so many repairs are finished on the first visit.
Annual Boiler Service
A yearly service before heating season keeps a boiler efficient and catches small problems before the first cold snap. We check combustion and venting, test the pressure relief valve and low-water cutoff, verify the expansion tank charge, inspect the circulators, clean the condensate trap on high-efficiency units, and bleed air from the system.
Boiler Replacement
When a boiler is past repair, we size the new one from a heat-loss calculation rather than copying the old nameplate β older boilers were often oversized, and a right-sized high-efficiency condensing boiler can cut fuel use noticeably. A combi boiler can also take over your domestic hot water, replacing a separate water heater. We handle the venting, the gas line and the near-boiler piping, and you get a written price before we start.
Baseboard and Radiator Systems in Older Homes
Some older homes in Fourth and Gill, Old North Knoxville and Sequoyah Hills still heat with hot-water baseboard or cast iron radiators. We keep those systems running: bleeding and balancing so every room heats evenly, replacing leaking valves and sections, swapping worn circulators, and adding zones or a modern boiler without giving up the radiators.
Schedule Boiler or Radiant Heating Service
We serve Knoxville, Farragut, Maryville, Oak Ridge, Powell, Lenoir City and the rest of Knox, Blount, Anderson and Loudon counties. Call (865) 284-2424 β we're licensed and insured, TN CMC-A #83354.
Frequently Asked Questions
It depends mostly on whether the floor is open. Tubing laid in a new slab or before subfloor goes down costs far less than retrofitting under a finished floor, and the boiler or water heater that supplies it is a separate cost. We give a written estimate after a heat-loss calculation for your space.
Often, yes. If there's an open basement or crawlspace below, we can staple tubing with aluminum heat-transfer plates to the underside of the subfloor without touching the finished floor above. On a slab with no access below, a thin pour over the slab is an option when you're replacing the flooring anyway.
In the right space, yes: slab basements, tile floors, additions, new builds and shops. For heating a whole existing house, a heat pump is usually the better value here, and we'll tell you that up front.
A well-maintained cast iron boiler often lasts 20β30 years, and a high-efficiency condensing boiler typically 15β20 years. Annual service and clean system water make the biggest difference to lifespan.
Usually the system pressure is too high, most often because the expansion tank has lost its air charge or the fill valve is letting in too much water. Don't cap or plug the valve β it's a safety device. Call us and we'll find the cause.
Once a year, ideally in early fall before heating season. Annual service catches failing pumps, low expansion tank pressure and venting problems before they leave you without heat on a cold night.